SOLAR GENERATOR · SOLAR + BATTERY, NO ENGINE

36 kW off-grid mobile solar generator: 16 panels over a 74.2 kWh lithium bank in 14 modules.

16 × 460 W panels make 31.6 kWh a day into a 52 Vdc bank. Below 1.32 kW the sun covers the whole load and it runs indefinitely — no fuel, no exhaust, nothing to hear.

Continuous
36kW
DC bus
52V nom
Stored
74.2kWh
Solar / day
31.6kWh
Trailer
3axles
123-SG-7DE7 — The solar trailer hitched to a service truck, panels stowed, on a desert site

Overview

How this machine carries the load.

123-SG-7DE7 is a 36 kW off-grid mobile solar generator with no engine: 16 panels at 460 W each, a 74.2 kWh lithium iron phosphate bank across 14 modules, and an inverter rated 36 kW off-grid, all carried on a three-axle trailer. It suits sites that need heavy continuous power without noise, exhaust or a fuel delivery.

The inverter sets the 36 kW rating, delivering 120/240 V or 120/208 V at 50/60 Hz, with a 5 ms transfer and 97% conversion efficiency. It surges to 72 kW for 10 seconds — enough to start compressors, pumps and heavy motors. The bank behind it can deliver 80.08 kW at 52 V, so the inverter, not the battery, sets the limit at every load this machine is rated for, and full output holds for as long as there is energy in the bank.

The 7.36 kW array harvests 31.6 kWh on an average day, and below 1.32 kW the sun carries the load on its own, indefinitely. Above that threshold the bank takes over: 37.1 kWh usable at the standard 50% setting carries 6 hours at 6 kW, 3 hours at 12 kW, 2 hours at 18 kW, or 1 hour at the full 36 kW with no sun at all — stretching to 51.94 kWh if the bank is programmed to the 30% option.

The array feeds the inverter directly, so there is no separate charge controller to fit or to fail, and the machine runs across an ambient range of +14 to +131°F (-10 to +55°C). That range and the 36 kW rating make the 123-SG-7DE7 a fit for data centers, heavy construction, utilities, and oil and gas sites that draw hard around the clock, moved and set up with one tow.

Every 123eSolar system is SMART enabled, with cloud IoT monitoring and control reachable from a phone or desktop, so operators manage the site without making a trip to it.

Features and benefits

  • 36 kW continuous off-grid inverter at 120/240 V or 120/208 V, 50/60 Hz — Heavy site loads run at full rating without derating, and sensitive electronics ride through a change of source.
  • 72 kW surge for 10 seconds — Motor and compressor starts don't trip the supply or force an oversized machine.
  • 74.2 kWh lithium iron phosphate bank across 14 modules at 52 V — A full shift of heavy draw runs silently, with no fuel, no exhaust and no engine to service.
  • 7.36 kW nameplate array, 16 panels at 460 W each — Light, steady loads run indefinitely with no fuel delivery, no service call, and no site visit.
  • Bank able to deliver 80.08 kW at 52 V, well above the inverter's own rating — Full 36 kW output is available for as long as the bank holds charge.
  • No separate charge controller: the inverter takes the 7.36 kW array directly — Quicker commissioning on arrival, and one less component to maintain in the field.
  • Cloud IoT connectivity standard on every 123eSolar machine — Field teams get visibility and control without a site visit.

Performance

Performance across the load range.

Zero to 36 kW, the rated maximum.

How long the battery carries the load on its own. Below 1.32 kW the array carries the whole day and the machine runs indefinitely. Above it, these are the hours the bank lasts with no sun and nothing charging, at the standard 50% setting and at the 30% setting.
012.52537.5501.3261218243036rated continuous 36 kWbelow 1.32 kW it runs indefinitelycontinuous load, kWhours on the battery alone

battery only, 50% settingbattery only, 30% settingthe array carries the whole dayrated continuous output

Performance of 123-SG-7DE7 at each continuous load
Loadcontinuous, 24 h Solar generationthe array, per day Battery only Daily drawload × 24 h After solar Days of autonomy
1.32 kWsolar break-even 31.6 kWh 27.29 h / 38.21 h 31.6 kWh covered indefinite
6 kW 31.6 kWh 6 h / 8.4 h 144 kWh 112.4 kWh 0.32 days
12 kW 31.6 kWh 3 h / 4.2 h 288 kWh 256.4 kWh 0.14 days
18 kW 31.6 kWh 2 h / 2.8 h 432 kWh 400.4 kWh 0.09 days
24 kW 31.6 kWh 1.5 h / 2.1 h 576 kWh 544.4 kWh 0.07 days
30 kW 31.6 kWh 1.2 h / 1.68 h 720 kWh 688.4 kWh 0.05 days
36 kW 31.6 kWh 1 h / 1.4 h 864 kWh 832.4 kWh 0.04 days

Every load here runs continuously, and the day is 24 hours — daily draw is the load × 24 h, so 2 kW is 48 kWh. A load that runs an 8-hour shift draws a third of the figure shown and lasts three times as long. Battery-only hours are given at both state-of-charge settings. Solar is a daily energy offset, not an instantaneous power match — over a day it balances, within a day it is not a guarantee of cover.

Size it for your site

Your load, on 123-SG-7DE7.

Most sites swing between a low and a high. Enter both, and the hours a day spent at the high, and the figures follow your day rather than a flat worst case. The load is yours — nothing is assumed until you enter it, and nothing that names you is kept; the PDF button builds the engineering sheet from the figures you enter.

Read from the performance table above: engine hours and fuel follow the day's energy, so your day is read at its average load; solar is the published daily figure; battery-only hours are the published bank at your high load. A load held for 24 hours is the worst case at that level. With no days entered it runs indefinitely; a week and a year are your day repeated, at the same sun.